• Link to LinkedIn
  • Link to Mail
  • cs_CZCS
  • elEL
  • pl_PLPL
  • da_DKDA
  • sv_SESV
  • es_ESES
  • it_ITIT
  • fr_FRFR
  • en_GBEN
  • de_DE_formalDE
Lobaro GmbH | Hamburg | Germany
  • Shopping Cart Shopping Cart
    0Shopping Cart
Lobaro.com
  • Products
    • Overview
    • Documentation (EN)
  • Lobaro Platform
    • Product description
    • Metering connections
    • Wireless M-BUS Parser
  • FAQ
    • FAQ
    • Returns
  • The company
      • Team
      • Jobs
      • Partner
    • Compliance
      • Environment
      • Waste disposal
      • Battery safety
  • Contact us
    • Imprint
  • Menu Menu

Hybrid gateway (ext. power, 230V)

The Lobaro Hybrid Modbus Gateway ext. Power, 230 V is equipped with external connections for RS485 / Modbus, Ethernet / LAN. It is compatible with Modbus ASCII / RTU. It can also be operated with 230 V via power supply unit or 12-24 V. The upload takes place via NB-IoT mobile radio (LTE bands: 3, 8, 20) or alternatively via LoRaWAN v1.0.2 (EU-868).

Note: Please use the Lobaro USB configuration adapter also order.

Request for quotation via e-mail: sales@lobaro.com

Save page as PDF (German)
SKU: 8000166 Category: Cancelled Tag: modbus
  • Description

Description

The Lobaro Hybrid Gateway ext. Power, 230 V is an easy-to-use, cost-effective and energy-efficient device that reads data via Modbus from any number of Modbus-capable devices, stores it temporarily and forwards it to the Internet.

The gateway can be used for communication with Modbus slave devices (ASCII/RTU on an RS-485 bus) via NB-IoT, LTE-CatM1, LoRaWAN or LAN. Modbus commands can be transmitted to the gateway via downlink message and are forwarded by the bridge to the connected slave devices. Received responses are forwarded as uplink messages to the Lobaro IoT Platform. The Modbus gateway can also be configured to regularly execute Modbus commands and report the responses at the time of execution.

The Modbus gateway supports reading all four register types that can be provided by Modbus slave devices: Coil, Discrete Input, Input Register, and Holding Register. It also supports writing values to all writable registers: Coil and Holding Register. Several different slave devices on the bus can be accessed individually from a single gateway device, even if the slave devices have a different Modbus configuration. In order to fulfil individual requirements, read intervals and register definitions can be configured very flexibly.

In normal operation, all actions of the device are controlled by an individually configurable scheduler, which executes the list of jobs in sequence. Only one job is executed at a time. The jobs generate uplink messages that are uploaded. After each uplink sent, the device searches for downlinks coming from the network (this happens for both LoRaWAN and LTE configurations). Downlink Modbus commands are currently only supported for LoRaWAN.

The daily status uplink ensures that the device can be reached for remote configuration within 24 hours, regardless of the current configuration.

Order information

  • Type designation: LOB-GW-DINRAIL-HYB-MODBUS
  • Article number: 8000166 - Hybrid Modbus Gateway (ext. Power, 230V)
  • Brief description: Hybrid Modbus gateway (ext. power, 230V) with external antenna and double cable feed-through

Technical data

  • Upload via NB-IoT mobile radio (LTE bands: 3, 8, 20)
  • SIM card (4FF / Nano) - not included
  • Alternative upload via LoRaWAN v1.0.2 (EU-868)
  • Compatible with Modbus ASCII / RTU
  • Compatible with wireless M-BUS S1, C1/T1 modes (868 MHz) counters
  • Compatible with Xylem Sensus RF Bubble Up (868 MHz)
  • Compatible with Müller radio (ME protocol, Walk-By) for µon and µflow skyW-2 and skyE-2
  • Online configuration: transmission intervals, filter: meter ID, manufacturer, device type
  • Signed firmware updates (FOTA) via NB-IoT
  • Power supply: 230 V via mains adapter or 12-24 V
  • IP54 housing: 130 mm (l) x 130 mm (w) x 75 mm (h)
  • Incl. articulated rod antenna 10.8cm
  • Temperature range: 0°C to +55 °C
  • External connections: RS485 / Modbus, Ethernet / LAN

Also available as a variant without power supply unit for the top-hat rail: 8000159 

Configuration

We recommend using the Lobaro Configuration Adapter and the Lobaro Maintenance Tool for easy configuration of the device. Detailed information on commissioning and configuration can be found in our documentation

https://doc.lobaro.com/display/PUB/Hybrid+Modbus+Gateways

Lobaro IoT platform

To evaluate the product, you can use the free test instance* of the Lobaro IoT platform available on our server. For production systems, please contact us about installing the platform on your server or AWS or connecting the hardware directly.

*Without availability guarantees, without backups, trial period: 6 months from purchase

Further documentation

Online documentation (EN)

Related products

  • Multi temperature sensor (1-wire)

  • Level sensor V3

  • Lobaro wireless M-Bus Solargateway

    Wireless M-Bus Gateway (Solar)

  • Hybrid Gateway V2 (battery)

Lobaro is LoRa Alliance Member
NB-IoT Logo
Lobaro is Nordic Design Partner
Lobaro GmbH | Osterbekstrasse 90c | 22083 Hamburg | Germany | sales@lobaro.de | Tel.: +49 40 228165310
  • Link to LinkedIn
  • Link to Mail
  • Imprint
  • GTC
  • Data protection
  • Waste disposal
  • Discontinued products
Link to: Hybrid Gateway (ext. Power, Din-Rail) Link toHybrid gateway (ext. power, Din-Rail) Hybrid gateway (ext. power, Din-Rail)Link to: Hybrid Gateway V2 (Batterie) Link toHybrid Gateway V2 (battery) Hybrid Gateway V2 (battery)
Scroll to top Scroll to top Scroll to top

Our website uses cookies. By continuing to use the website, you consent to the use of these cookies. You can find more information about cookies in our

Privacy policyOK

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refusing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Privacy Policy

You can read about our cookies and privacy settings in detail on our Privacy Policy Page.

Data protection

Accept settingsHide notification only
We have detected that you may not speak German. Would you like to change the language of our website to:
de_DE_formal Deutsch (Sie)
de_DE_formal Deutsch (Sie)
fr_FR Français
da_DK Dansk
es_ES Español
it_IT Italiano
sv_SE Svenska
pl_PL Polski
en_GB English (UK)
cs_CZ Čeština
el Ελληνικά
Change Language
Close and do not switch language